Mechanical strabismus

H7_STRABMECH

Endpoint definition

Endpoint definition steps

FinnGen

Phenotype data

520210

1. Apply sex-specific rule

None

520210

2. Check conditions

None

520210

3. Check pre-conditions, main-only, mode, registry filters

Registry filters:

  • Hospital discharge: ICD-10 H50.6
  • Cause of death: ICD-10 H50.6

2 out of 7 registries used, show all original rules.

81

4. Check minimum number of events

None

81

5. Include endpoints

None

81

6. Filter based on genotype QC (FinnGen only)

81

Control definitions (FinnGen only)

Control exclude
H7_OCUMUSCLE

Extra metadata

Level in the ICD hierarchy
4
First used in FinnGen datafreeze
DF2
Parent code in ICD-10
H50
Name in latin
Strabismus mechanicus

Case counts by codes

FinnGen case counts by registry codes:

generic upset plot

Upset plot

Full data table

Summary Statistics

-FinRegistry-

Key figures

All Female Male
Number of individuals
Whole population 628 362 266
Only index persons 526 307 219
Unadjusted period prevalence (%)
Whole population 0.01 0.01 0.01
Only index persons 0.01 0.01 0.01
Median age at first event (years)
Whole population - 33.99 31.00
Only index persons 44.68 45.23 43.92

-FinnGen-

Key figures

All Female Male
Number of individuals 81 56 25
Unadjusted period prevalence (%) 0.02 0.02 0.01
Median age at first event (years) 54.61 51.62 61.29

-FinRegistry-

Age distribution of first events

-FinnGen-

Age distribution of first events

-FinRegistry-

Year distribution of first events

-FinnGen-

Year distribution of first events

-FinRegistry-

Cumulative Incidence Function

-FinnGen-

Cumulative Incidence Function

No data

CodeWAS (R11)

CodeWAS is a tool for exploring the associations between an endpoint and all of the medical codes and drug codes.

This is a new tool, please reach out using the contact form for feedback and improvement ideas.

First, a cohort is built by matching controls to the endpoint cases using year of birth and sex. Then, a Fisher test is done for all the medical codes and drug codes between the cases and controls of this cohort. Codes are reported in the table below if they have −log10(p-value) ≥ 6.

Matched cohort

Matched cases
71
Matched controls
709
Code
Vocabulary
Description
Odds Ratio
-log10(p)
N matched cases
N matched controls
H50.6
ICD-10 Finland
Mechanical strabismus
+∞
102.0
71
*
H53.2
ICD-10 Finland
Diplopia
94.3
30.4
32
6
H06.2*E05.9
ICD-10 Finland
Dysthyroid exophthalmos
150.5
28.1
28
*
CEC00
NOMESCO Finland
Recession of extraocular muscle
+∞
26.8
24
*
CEW99
NOMESCO Finland
Other operation on extraocular muscle
+∞
24.4
22
*
H50.2
ICD-10 Finland
Vertical strabismus
+∞
22.0
20
*
H06.2
ICD-10 Finland
Dysthyroid exophthalmos
+∞
20.8
19
*
CEC60
NOMESCO Finland
Transposition of extraocular muscle with adjustable suture
+∞
20.8
19
*
H50.0
ICD-10 Finland
Convergent concomitant strabismus
+∞
20.8
19
*
E05.0
ICD-10 Finland
Thyrotoxicosis with diffuse goitre
24.9
20.3
29
19
XCW99
NOMESCO Finland
Other investigative procedure of eye
14.1
17.8
33
41
H50.8
ICD-10 Finland
Other specified strabismus
+∞
12.9
12
*
H03BB01
ATC
carbimazole; oral
12.7
12.1
22
24
CA1BG
NOMESCO Finland
Eye and orbita MRI examination with high intensity magnet
142.1
11.8
12
*
CE2W4
NOMESCO Finland
Eye movement mapping
+∞
11.8
11
*
CEC10
NOMESCO Finland
Recession and resection of extraocular muscle
+∞
10.7
10
*
E05.9
ICD-10 Finland
Thyrotoxicosis, unspecified
13.4
9.4
16
15
H03AA01
ATC
levothyroxine sodium; systemic
5.1
9.2
37
125
CEC90
NOMESCO Finland
Total transposition of extraocular muscle or muscles
+∞
8.5
8
*
WX100
NOMESCO Finland
Conjunctival surface anesthesia
7.8
8.5
20
34
XCD10
NOMESCO Finland
Electrophysiological examination of eye
38.2
8.3
10
*
WF002
NOMESCO Finland
Radical radiotherapy
14.1
8.0
13
11
ZXA10
NOMESCO Finland
Bilateral
5.1
7.9
28
80
CK2X4
NOMESCO Finland
Optical coherence tomography (OCT) of ocular fundus
8.6
7.9
17
25
S01CA01
ATC
dexamethasone and antiinfectives; ophthalmic (ophth., corticosteroids and antiinfectives in comb.)
4.3
7.7
38
151
CA1CG
NOMESCO Finland
Eye and orbita extensive MRI examination with high intensity magnet
89.0
7.6
8
*
CAC30
NOMESCO Finland
Decompression of orbit to sinuses
+∞
7.4
7
*
CAC10
NOMESCO Finland
Reconstruction of orbital wall using bone graft or plate
+∞
7.4
7
*
H50.1
ICD-10 Finland
Divergent concomitant strabismus
+∞
7.4
7
*
CAC44
NOMESCO Finland
Combined decompression of orbit
+∞
7.4
7
*
S02.30
ICD-10 Finland
Fracture of orbital floor, closed
76.4
6.5
7
*
CEC30
NOMESCO Finland
Resection of extraocular muscle
+∞
6.3
6
*
ZX050
NOMESCO Finland
Stereotactic radiotherapy
+∞
6.3
6
*
CS444
NOMESCO Finland
Visual field testing with Octopus automated perimetry
14.3
6.3
10
8
L04AX03
ATC
methotrexate; systemic (immunosuppressants)
5.7
6.2
18
40

Mortality – FinRegistry

Association

Association between endpoint H7_STRABMECH and mortality.

Females

No data

Males

No data

Mortality risk

Mortality risk for people of age

years, who have H7_STRABMECH.

N-year risk Females Males
1 No data No data
5 No data No data
10 No data No data
15 No data No data
20 No data No data

Relationships between endpoints

Index endpoint: H7_STRABMECH – Mechanical strabismus

GWS hits: -

Endpoint
Case Overlap
Survival Analysis
Genetic Correlations
Genetic Signals
N (Jaccard index)
HR [CI]
Extremity
rg [CI]
Extremity
Hits
Coloc Hits
FinRegistry
FinnGen
FinRegistry
FinnGen
FinnGen
loading spinner Loading data